AXIS#.EIP.UNWIND

Description

This parameter allows modifying and configuring the rollover modulo value used when calculating internal drive position units from EtherNet/IP user units received by the drive. Position units sent to the drive by the fieldbus master should be less than or equal to this value for correct behavior.

Context

For more information regarding this parameter see CIP Sync Configuration Parameters.

Versions

Action Version Notes
Implemented 02-11-00-001

General Information

Type

Read Write

Units

N/A

Range

100 to 2,147,483,647

Default Value

360000

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

EtherNet/IP drives: AKD2G-SPI

Fieldbus Information

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

7538

1

7538 (0x1d72)

AXIS1.EIP.UNWIND

Signed32

Read/Write

Yes

73074

2

7538 (0x1d72)

AXIS2.EIP.UNWIND

Signed32

Read/Write

Yes